Symptoms
|
Possible
Causes
|
Solution
|
| The
switch can only operated be via the faceplate button. |
There
is no battery or weak battery in the remote controller.
The
channel selector setting is wrong.
|
- Put
in the batteries provided or replace with new batteries.
- Put
the jumper into the appropriate channel selector location.
|
| The
switch and remote controller is working previously but is not working
now.
|
- Blown
fuse.
- Blown
bulb/lamp.
- Lighting
circuit exceeds 300 W per gang specifications.
- For
dual gang only,the bulb for L1 has blown.
- The
JDO electronic switch is faulty..
|
- Replace
fuse.
- Replace
bulb/lamp.
- Reduce
the lighting circuit/no of bulbs/luminaire types to comply with
the 300 W specifications.
- Replace
the blown bulb.
- Send
it back to the authorized agent for repair.Do not attempt the
repair yourself as the JDO switch has no serviceable parts.
|
-
Using
the remote controller turns on several lighting circuit simultaneously.
|
- The
channel selector jumper(s) has not be selected to operate on
other channels.
- The
switches is located in the same big hall but at different locations.
|
- Reselect
the appropriate channel in the channel selector.
- Select
another channel for one of the switches.
|
| The
fluorescent lamp flickers and may have some humming sound. |
- The
ballast used is of the electronic ballast type,which is incompatible
with JDO switch.
|
- Replace
the electronic ballast with the normal magnetic ballast.
|